Čeština (Česká republika)English (United Kingdom)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Úvod Aircraft systems Products LUN 1792

LUN1792 - Analog signal converter

There are no translations available.

FunctionDescription

The LUN1792 unit converts analog signals of vertical deviation, lateral deviation and signals of vertical and lateral deviation validity from main output of GNS 430W unit to format suitable for Russian navigation indicator NPP 1485MK or similar.

LUN1792OBS function

OBS is selected on GNS 430 unit only. For detailed OBS function description see „Pilot’s Guide & Reference“.To use OBS selection on NPP, you need to use LUN1794.3

Electrical parameters

Unit is powered by 28 VDC . Supply voltage should be within the range min. 16 VDC, max. 32 VDC. Recommended value of protection device ( fuse or circuit breaker) is 2 Amps. Device is designed to be supplied from aircaft electrical system in accordance with MIL-STD-704E. Unit is powered and all signals are connected via connector series MIL-C-38999, type MS27508E14, 37 pins.

General parameters
Power supply 14-32 VDC
Analog Inputs

4x diferential input, ±150mV, 12bit

Analog Outputs

2x diferential output, ±250mV, 12bit

Logic Outputs

3x Relay output

Input impedance 1kOhm ±1%
Output impedance max. 330 Ohm ±2%
Signal conversion error max ±1%
Operating temperature range
-40 - 70 °C
Storage temperature -55 - 85°C
Humidity max. 95%
Connector MIL-37
Dimensions 211x45x90 mm
Weight 500 g
Power consumption 5.0 W